Engines for GenSet
- 2013 год
Engines for GenSet
MAN marine engines (RMRS and RRRS) are optimal solution for regular and economic power supply for ships.
Famous manufacturers of marine power plants, emergency and auxiliary generating sets choose MAN engines as the reliable, long-lasting and economic equipment.
Engine model | Type | Continuous output power in accordance with ISO 8528, kW | Fan (pump) power take off | Bore/stroke/ Displacement | |||
Auxiliary (ADG-PRP)1) |
Emergency (EDG – LTP) 2) |
kW | mm/mm/l | ||||
kW | kVA | kW | kVA | ||||
D2866LXE20 | R6 | 190/224 | 177/190/244/270 | 11 |
128 / 155 12 |
||
D2866LXE30 * | (-) | ||||||
D2866LXE201 | R6 | 272/280 | 9 |
128 / 155 12 |
|||
D2866LXE301 | 327 | 9 | |||||
D2876LXE201 | R6 | 355 | 12 |
128 / 166 12,8 |
|||
D2876LXE203 | 410 | 14 | |||||
D2876LXE301 * | 345 | (3) | |||||
D2840LXE201 | V10 | 443 | 14 |
128 / 142 18,3 |
|||
D2840LXE203 | 495 | 14 | |||||
D2840LXE301 * | 443 | (3) | |||||
D2842LXE201 | V12 | 543 | 14 |
128 / 142 21,9 |
|||
D2842LXE203 | 575 | 14 | |||||
D2842LXE301 * | 532 | (3) |
* Engines with seawater cooled heat exchanger, power take off is indicated for seawater pump
1) PRP operation mode (for auxiliary diesel generators ADG) implies constant load, 10% overloads during 1 hour are allowed, but not longer than once in 12 hours.
2) LTP operation mode (for emergency diesel generators EDG) implies that operation time must not exceed 500 operation hours in a year, constant operation not longer than 300 hours at 100% load, overloads are not allowed. Engines provide emergency power supply for example during power supply failures of main feed power.
3) Electrical power of a typical generator with efficiency 92%-96% and cos(φ)=0,8. Engines are supplied with generators for assembly. Also installation as a gear for compressors and pumps is possible.