CHP units

 

 

 General:

Gas-fueled power units in soundproof shield, frequency 50 Hz, voltage 400 V, 3-phase alternating current. 

 

 

 

MAN gas-fueled power units on natural gas

Station model Power

Efficiency (general) 

 

      

Engine model Gas consumption at 100 % load 
Electrical (COP – Continuous Power) Thermal (maximal)
kW kW %

m3/h

GGK35M 35 55 80,45 MAN E0834 E312 11,1
GGK50M 50 79 88,17 MAN E0834 E302 15,3
GGK70M 70 109 88,17 MAN E0836 E302 20,8
GGK100M 100 145 87,22 MAN E0836 LE302 27,7
GGK130M 130 193 91,54 MAN E2676 E302 36,1
GGK150M 140 207 89,28 MAN E2876 E312 40,3
GGK200M 200 283 85,95 MAN E2876 LE302 54,2
GGK200M 200 267 88,03 MAN E2676 LE202 54,2
GGK200M 200 284 87,78 MAN E2876 LE212 56,9
GGK250M 250 374 91,50 MAN E3262 E302 75,1
GGK300M 300 382 87,12 MAN E3268 LE242 77,8
GGK350M 350 443 87,42 MAN E3268 LE212 94,4
GGK400M 400 548 86,54 MAN E3262 LE232 115,3
GGK500M 500 645 85,90 MAN E3262 LE202 141,7

MAN gas power units on special gas (drilling gas, biogas, sewage gas, pyrolysis gas and landfill gas)

Model   Power Efficiency Engine  Gas consumption at 100 % load
Electrical (to be specified depending on gas composition) Thermal
kW kW % m3/h
GGK60M 60 to be specified depending on gas composition MAN E0834 LE302 to be specified depending on gas composition
GGK70M 70 MAN E0834 LE322
GGK100M 100 MAN E0836 LE302
GGK130M 120 MAN E2876 TE302
GGK200M 180 MAN E2876 LE302
GGK200M 200 MAN E2876 LE202
GGK200M 200 MAN E2676 LE212
GGK300M 300 MAN E3268 LE252
GGK300M 300 MAN E3268 LE262
GGK350M 350 MAN E3268 LE222
GGK350M 350 MAN E3268 LE232
GGK400M 400 MAN E3262 LE242
GGK500M 500 MAN E3262 LE212

Power unit scope of supply

1. MAN gas engine (Germany)
2. Single-bearing generator Leroy Somer (France)
3. Welded steel frame with antivibration mounts
4. Lubrication system with water-oil radiator and filter
5. Fuel system with fuel filters, microprocess throttle control unit and gas metering device
6. Heat recovery system installed on one frame with gas power unit
7. Inlet system with air filter
8. Exhaust system with silencer and expansion joint

Control system

Control system is based on microprocess controller that provides parallel operation of cogeneration plant in auto mode. It consists of operator’s display with software and cable 25 m. The system carries out parallel operation of units with automatic load distribution by ensuring the following:

1. Independent automatic mode
2. Parameter control function of cogeneration plant
3. Emergency alarm
4. Operation visualization
5. Operator’s software
6. Close monitoring
7. Function of parallel operation with circuit
8. Parallel operation mode of typical plants

Specified life limit till overhaul is 50 000 (60 000 for non-turbine) operating hours if technical maintenance and operation instructions are observed. After 50 000 (60 000 for non-turbine) operating hours it is necessary to carry out major overhaul of the engine and replace such items as crank bearings, pistons, rings, sleeves or replace entire diesel engine.

 